Cummins Calterm v5.16 (5.16.0.417 + MetaFiles)

[12/2024]
Diagnostic Software Cummins Calterm v5.16 (5.16.0.417 + MetaFiles)
Type of catalogue: Diagnostic Software
Make: Cummins
Region: WorldWide
Inclusive
languages:
English
Amount of
disks:
1 CD
OS: Windows 8/8.1 32 bit, Windows 8/8.1 64 bit, Windows 10 32 bit, Windows 10 64 bit, Windows 11 64 bit, Windows 11 Pro 64 bit
Price, USD: 150

Calterm: Calibration Terminal v5.16.0.417

Available editions: 

  • Engineering
  • FieldEngineering
  • Production

If you need a particular edition, please let us know in the comments field.

Important Notice: If you are running OS Windows 7, we can offer you Calterm 4 v4.7.1.007, the last supporting Windows 7 platform. Please indicate it in the comments field. 

Release Notes for Calterm v5.16.0.417

A new version of Calterm v5.16.0.417 has been released. This release includes the following features and bug fixes:

Release Contents for Calterm v5.16.0.417:

  • New product support
    • BTV, BTW, BTX, BTY, BUA, BUB
  • New Features and Improvements:
    • EPK check for CSAR
    • SPEED NextGen Support
    • XCP Authentication
    • eFPA file extraction for CoreII
    • Inhibit Downgrade Feature - Pretool check for Core II
    • Routines support for CSAR
    • Enumeration Parameter Datatype Change in Calterm
    • Detect and connect to the devices with Stellantis address 0x10
    • Improved PDL errors
    • PHY_UNIT support
  • Critical Issues/Defects:
    • Calterm 5.11 Crashing for AhccExhPrMfm.CaExhPrMfmVect
    • Calterm crashes when copying the AhccExhPrMfm.CaExhPrMfmVect values from Excel
    • Calterm crash when open and close CORE2 files for multiple times
    • Calterm throwing error when copying the table parameters values from Excel
    • Table cells are not highlighting correctly after virtualization is enabled
    • CSAR user reported any issue in copying the table parameter break points
    • XCP on CAN connection failed on v5.12.1.0.18, same setup working with v5.12.0.066
    • Calterm 5.13.0.35 - Datalink options missing for smart device reflash
    • Calterm does start monitoring the parameters and faults after performing the toggle security in Calterm5.12
    • Calterm not able to export unit information of tables for CDFX file
    • The toggle security key is not working in Calterm5.12.0 and 5.13 protected Calterm version
    • Calterm 5.8 stops monitoring parameters in screenfile and ASAM when performing overnight testing on 2450A
    • CSAR lookup parameters are unable to show correct values when converted in hex
    • Calterm 5.13 easy to get stuck with Create screen file function
    • Overlay fails with XML file in core2 with Calterm5.13.1 version
    • Overlay failed on Calterm5.13.1 when performing xml to xcal overlay for CAGT_Block_Fault_Codes, CAGT_Block_Fault_CodesCFTR_Block_Lamp_Fault_Codes
  • Note:
    • License Configuration Tool and Update Manager will be installed as pre-requisites for Calterm.

Following are the release contents for Calterm v5.12.1.028

New product support

New Features/Change Requests

Critical fixes and Improvements:

  • BTF, BPQ
  • Protected Calterm doesn’t support reconnection after key cycle for CSAR ECM
  • User impact: User will be able to connect ECM automatically after key cycle.
  • CSAR Cyber 1a feature support: ODX-F End to End Calibration Encryption, Digital Signature, UDS Bi-directional Session Authentication.
  • User Impact: User will be able to reflash digitally signed CSAR ECM with encrypted Odx-f file, existing CSAR ECM will work as it is.
  • License-based CSAR reflash with Tool family and setting secure key
  • User impact: user can reflash CSAR ECM with other tool family other than Calterm and set different security key if the user has a license.
  • Please add warning messages when the parameters limit is exceed in ASAM
  • User impact: user can add parameter within limit to avoid further issues.
  • Calterm does not open (Structure and StructureArray) parameters when save to screen file.
  • User Impact: User will be able to open structure and StructureArray from screen file as well.
  • CSAR - Calterm Connects to CSAR module without any ECM connected with AutoLogging checked.
  • User Impact: Validations are applied so Calterm will notify to user that ECM is not connected.
  • Calterm 5.12 lost the ability to Files->create screen file between UAT build 60 and 64
  • User Impact: User will be able to open “Create screen file” menu.
  • CALTERM freezes after opening the CSAR Calibration Download window when only ASAM connection to the ECM is established
  • User Impact: Calterm UI will not freeze.
  • Calterm crashes when copying the AhccExhPrMfm.CaExhPrMfmVect values from Excel
  • User Impact: Partially fixed. Details are on the next slide.
  • 12323702 Calterm 5.11 Crashing for AhccExhPrMfm.CaExhPrMfmVect is partially fixed because of Telerik limitation
  • User Impact: User will see Calterm crashing but high-lighting (yellow for values changed) can be seen on visible screen only. Data will NOT be lost. The request has been raised to the Telerik forum.

The new version of Calterm 5.12.1.028 is the engineering development and testing tool used to monitor the Electronic Control Module (ECM) for the Cummins engine system and to alter the calibration data contained therein. 

What functions do you think can be performed using Calterm v5?

  • Perform Installation Quality Assurance testing
  • Perform DPF regeneration
  • View active and inactive fault codes
  • Troubleshoot integration issues
  • Troubleshoot calibration issues
  • Collect engine/AT test data

Cummins Calterm can be used to:

  • monitor ECM or any J1939/Datalink device parameters
  • temporarily change calibrations
  • View and erase fault codes
  • log ECM and J1939/Datalink parameters

When to use Calterm 5 and not Insite™?

There are several instances when Calterm is a preferred tool over Insite™:

  • Calterm 4 allows the user to access additional parameters in the ECM
  • Calterm 4 can log data at a faster rate
  • Calterm 4 allows a user to temporarily change calibrations and override parameters during testing

The supported DLA kits for Cummins Calterm

[Diagnostic adapter interface] Cummins Inline 7 Data Link Adapter

The software config file is a text file that contains and assigns the engine parameters, along with their scaling and location inside the ECM memory.

There are two types of software configuration files:

  • .e2m (Core 1 products e.g EPA 2004 and below)
  • .ecfg (Core 2 products e.g Above EPA 2007)

System requirements

  • Windows 8.1, 10. 11 x86/x64 Bit Platforms
  • At least 5 Gb of free space on your HDD
  • Cummins Hardware interface to establish a connection between the vehicle ECM and Cummins Calterm software

Screenshots for Cummins Calterm v5.16 (5.16.0.417 + MetaFiles):

Our company provides for sale original spare part catalogs, workshop manuals, diagnostic software for all models of engines, cars, trucks, buses, forklifts, tractors, harvesters, cranes, buldozers, generators, construction and agricultural machines, motorcycles. To purchase a catalog online, please add the product to your cart, fill in the contact form online. Our managers proceed your order the same day.

Related products for Cummins Calterm v5.16 (5.16.0.417 + MetaFiles):